Modular Polarimeter:
MCP
- Economic analysis of optical rotation that’s fully pharma-compliant
- Measuring accuracy of ±0.003 °OR that exceeds pharmacopoeia requirements
- Full range of pharma features and data integrity solutions
- Up to eight different wavelengths (365 nm to 880 nm)
- Plug-and-play connectivity to central data management software AP Connect
Measure. Comply. Perform. Our automated, digital MCP polarimeters series is optimized for highly regulated industries, such as the pharmaceutical industry. These high-performance instruments provide optical rotation measurements with a precision up to <±0.0020° OR, top data integrity standards, and full compliance to 21 CFR Part 11. What’s more, if your needs change, our digital polarimeter changes with you. With their multiwavelength options, you can easily adapt them for future needs. Fast measurement results are delivered in seconds, and the broad portfolio matches every budget.
Key features
Comply with pharma standards and master any audit
We’ve leveraged more than 15 years of experience in pharmaceutical applications to develop easy-to-use instruments compliant with industry standards (e.g., GMP, GAMP 5). Our MCP polarimeters’ software doesn’t just have mandatory 21 CFR Part 11 functions (e.g., audit trail), it’s also designed for convenience.
- Access control and comprehensive user privilege management
- Windows active directory log-on (desktop software)
- Encrypted, digitally signed data in file format or database
- Central data management with AP Connect (server client solution)
Rely on our comprehensive qualification documentation to keep your costs down
We know that passing an audit is a must. With our Pharma Qualification Documentation (PQP), which has been proven in hundreds of successful audits, this is easier than ever. IQ/OQ/PQ, a risk analysis, and a 21 CFR Part 11 checklist are included as well. Save up to 75 % of time for instrument qualification and validation of your MCP with our Pharma Qualification Packages.
What’s more: No matter your location, our qualification team is ready to help you qualify your instrument for seamless integration into your processes – on-site.
Prevent errors and meet your efficiency targets
The MCP series of instruments comes with various features designed to prevent errors, saving you stress, time, and money. Clear and definable user group privileges as well as password rules and security settings are aligned to local IT rules. Avoid repeat measurements due to human error. The FillingCheck™ camera delivers real-time images of the filling process inside the sample cell. Toolmaster™ automatically transfers sample cell and quartz control plate data and temperature to the instrument software.
Keep training and maintenance efforts to a minimum
Whether it’s for initial user training or continued operation, our MCP polarimeters’ features keep your efficiency high and your costs low.
- Guided workflows for measurements prevent errors before they can occur
- (Semi-)automated workflows for system suitability tests (SST) and calibration to improve efficiency
- Fast and powerful temperature control minimizes cycle times between measurements
- LED light source that’s good for a lifetime keeps downtime to a minimum
Get peace of mind with our data integrity solutions
Depending on your application, you have different needs when it comes to data management and compliance. That’s why we offer three different solutions.
- Embedded system for stand-alone operation – ideal for those with smaller amounts of data who only want a single installation. It lets you qualify the software and use the instrument for electronic records.
- PC-controlled operation – the perfect solution if you’re generating large amounts of data and you don’t want to have data and system administration on the instrument.
- AP Connect for central data management – you can also integrate several instruments into our data management hub. This is the perfect solution for those who need to run a powerful data management software independent of instruments, or intend to make use of the AP Connect interfaces to various systems (e.g., ERP, LIMS).
So whatever your data volume or IT policy, you can be sure we have a solution for it.
Technical specifications
MCP 4100 | MCP 5100 | MCP 5500 | |
Specifications | |||
Measuring Scales | °Optical Rotation, °Optical Rotation (cell-length corrected), °Specific Rotation,°Specific Rotation (cell-length corrected), % concentration (g/100 mL, g/L, g/100 cm³, kg/m³), °International Sugar Scale (not temperature-compensated), mathematic functions, and user-definable scales | ||
Measuring range | ±89.9 °OR | ±89.9 °OR | ±89.9 °OR |
Accuracy | ±0.003 °OR across entire range | ±0.002 °OR across entire range | <0.002 °OR across entire range |
Repeatability | ±0.002 °OR | ±0.002 °OR | ±0.001 °OR |
Resolution | 0.001 °OR | 0.0001 °OR | 0.0001 °OR |
Available wavelenghts | 589 nm standard 365, 405, 436, 546, 578, 633, 880 nm opt. | 589 nm standard 365, 405, 436, 546, 578, 633, 880 nm opt. | 589 nm standard 365, 405, 436, 546, 578, 633, 880 nm opt. |
Temp. control range | Peltier temperature control 10 - 45 °C | Peltier temperature control 10 - 45 °C | Peltier temperature control 10 - 45 °C |
Temp. accuracy | ±0.1 °C | ±0.1 °C | ±0.03 °C |
Temp. control speed | 2 °C sample temperature gradient eliminated in less than 30 seconds. (100 mm stainless steel cell, re-filled with water) | 2 °C sample temperature gradient eliminated in less than 30 seconds. (100 mm stainless steel cell, re-filled with water) | 2 °C sample temperature gradient eliminated in less than 30 seconds. (100 mm stainless steel cell, re-filled with water) |
21 CFR Part 11 compliance | yes | yes | yes |
User Assistance Features | |||
FillingCheck™ camera | no | yes | yes |
Automatic detection of sample cell and quartz standard by Toolmaster™ function | yes wireless Toolmaster™ technology | yes wireless Toolmaster™ technology | yes wireless Toolmaster™ technology |
Automated calibration / adjustment process by Toolmaster™ function | yes | yes | yes |
Separate drying facility for sample cell (air pump) | no | optional | yes |
Data Management | |||
Data managment software for multiple instruments (AP Connect) | optional | optional | optional |
Desktop software controlled | optional | optional | optional |
Engineering | |||
Light source | LED | LED | LED |
Max. sample cell length | 200 mm | 200 mm | 200 mm |
Standards
AOAC
European Pharmacopoeia (Ph. Eur.)
US Pharmacopoeia (USP)
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Determination of Camphor by Polarimetry Application Reports
-
Determination of Glucosamine via Polarimetry Application Reports
-
E-Book - Field Guide to Food and Feed Testing Application Reports
-
Food | Apparent Purity of Sucrose and Technical Sugar Solutions Application Reports
-
Food | Sweet Condensed Milk - Polarimetric Determination of Sucrose Content Application Reports
-
Optical Rotation of Stevia Application Reports
-
Pharma | Amino Acids - Optically Active Zwitterions Application Reports
-
Starch Decomposition with Subsequent Polarimetric Content Determination Application Reports
-
MCP Series | White Paper Traceable Calibration Customer Reports and Publications
Similar products
Consumables, Accessories & Software
Consumables, Accessories & Software
Accessories & Software
Accessories & Software
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
GLASS WINDOW Ø 23.5 mm
MCP 4100 | 5100 | 5500
PROTECTION CAP, BLACK (SQUARE USB INTERFACE)
MCP 4100
RUBBER WASHER Ø 15.5 mm MATERIAL:
PERBUNAN
MCP 4100 | 5100 | 5500
GLASS WINDOW Ø 15.5 mm
MCP 4100 | 5100 | 5500
Quartz Control Plates with Automatic Detection
MCP 4100 | 5100 | 5500
- Toolmaster™ technology saves time with automatic data transfer
- Eliminates manual data entry, improving data security and accuracy
- Complies with ICUMSA and OIML international standards
- Wireless temperature measurement ensures traceable and reliable results
QUARTZ CONTROL PLATE, 50 °Z / 17 °OR TOOLMASTER WIRELESS
MCP 5100 | 5500
Sample Cells for MCP
MCP 4100 | 5100 | 5500
- Path length from 2.5 to 200 mm
- Different stainless steel classes and filling options
- Wireless data transfer between cell and instrument with Toolmaster technology
POLARIMETER TUBE, HASTELLOY B3, 100 mm TOOLMASTER WL, LÜR, VOL. 2 ml
MCP 4100 | 5100 | 5500
Lab Execution Software:
AP Connect Start
MCP 5100 | 5500
- Now: 100 % discount at checkout!
- Kickstart your paperless lab
- Featuring key benefits of the Standard edition
- Restricted to one instrument, single user access, one export rule
Lab Execution Software:
AP Connect Standard subscription license
MCP 5100 | 5500
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips
Lab Execution Software:
AP Connect Standard one-time license
MCP 5100 | 5500
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Top data quality: elimination of transcription errors
- Fast decisions: data at your fingertips
Lab Execution Software:
AP Connect Pharma subscription license
MCP 5100 | 5500
- Annual fee per instrument
- Time-saving processes: automatic, digital data transfer
- Assurance of lab data integrity
- Fast decisions: data at your fingertips
Lab Execution Software:
AP Connect Pharma one-time license
MCP 5100 | 5500
- One-time fee per instrument
- Time-saving processes: automatic, digital data transfer
- Assurance of lab data integrity
- Fast decisions: data at your fingertips