Modular Compact Rheometer:
MCR 72/92
- The robust one
- Equipped with a ball bearing motor
- For measurements in rotation (and oscillation for special applications)
- Ideal to measure your samples’ flow behavior
The two new members of the renowned Modular Compact Rheometer (MCR) series – MCR 72 and MCR 92 – are the two wisest choices for quick and easy rheological measurements. These real rheometer “pearls” from Anton Paar are streamlined for your daily lab routine, easy to use in a plug-and-play fashion, and available at an accommodating price. There is a range of accessories available for both models. The step-by-step software and special features like TruRay (integrated light), QuickConnect (fast and easy mounting of the measuring system), Toolmaster™ (automatic tool recognition and configuration), etc. guarantee excellent ease of use. For academic use, both instruments are available as an EDU Edition, including a special EDU package for teaching staff as well as EDU Student Packages.
Key features
Two models designed for your application
Two new rheometers are available: MCR 72 is equipped with a ball-bearing motor (very robust in use, no compressed air required) and MCR 92 with an air-bearing motor (highly accurate for sensitive samples). The two rheometers enable measurements in both rotational and oscillatory mode. The choice of rheometer depends on your application. To investigate the deformation and flow behavior of your sample (also at different temperatures), consider MCR 72. For observing sample structure, MCR 92 is recommended. Both instruments have a motor that lifts up the measuring head automatically to set an exact measuring gap. This gap is 100 % reproducible. MCR 72 and MCR 92 can both be equipped with temperature devices to cover a range from -50 °C to +400 °C.
Your key to accuracy – the motor technology
25 years of experience in one motor – you only get this with rheometers from Anton Paar. The air-bearing-supported synchronous EC motor deploys a frictionless synchronous movement of the rotor inside that enables the most sensitive and therefore most precise movements. Whether investigating solids or low-viscosity liquids your results are accurate across a wide viscosity range.
Step-by-step software
The intuitive RheoCompass™ software helps you to find the test template you need, customize tests and analysis definitions, export your data and generate reports. You are guided through your first rheological measurements with predesigned but individually adaptable templates, including integrated videos and pictures for extra support. Different accounts can be created for each operator working in the lab.
Unique features for easy handling and reproducible results
The highlight of these two rheometer models is the patented TruRay lighting of the measuring surface, which can be gradually regulated for a clear view of your sample. When changing between measuring systems, QuickConnect allows one-handed connection of the measuring systems and ensures fast, convenient system changes without the use of a screwing mechanism. Then, Toolmaster™ takes over by automatically recognizing the mounted tool and temperature units. Finally, the SafeGap feature ensures that the setting of the measuring gap is always identical for every measurement and exactly reproducible every time.
Experienced experts close to you
Anton Paar’s worldwide service network ensures that an expert on your system is always close by. One thousand installed instruments around the globe, an extensive application database, a website full of practical information (World of Rheology), the book “Applied Rheology – With Joe Flow on Rheology Road”, eLearning courses and numerous published works by our rheology experts confirm that Anton Paar is the first choice for answering any rheological question you may have.
Technical specifications
Specifications | Units | MCR 72 | MCR 92 |
Bearing | - | Ball | Air |
EC motor (brushless DC) with high resolution optical encoder | - | ✓ | ✓ |
Rotation Mode | - | ✓ | ✓ |
Oscillation Mode | - | ✓ | (1✓ |
Direct Strain Controller | - | ✓ | ✓ |
Direct Stress Controller | - | ✓ | ✓ |
Maximum torque | mNm | 125 | 125 |
Minimum torque, rotation | µNm | 200 | 1 |
Minimum torque, oscillation | µNm | 200 | 1 |
Torque resolution | nNm | 100 | 100 |
Angular deflection, set value | µrad | 1 to ∞ | 1 to ∞ |
Angular deflection, resolution | nrad | 614 | 614 |
Step rate, time constant | ms | 100 | 100 |
Step strain, time constant | ms | 100 | 100 |
Minimum angular velocity (2 | rad/s | 10-4 | 10-4 |
Maximum angular velocity | rad/s | 157 | 157 |
Minimum angular frequency (3 | rad/s | 10-3 | 10-4 |
Maximum angular frequency | rad/s | 628 | 628 |
Minimum speed (CSS/CSR) | rpm | 10-3 | 10-3 |
Maximum speed | rpm | 1500 | 1500 |
Maximum temperature range | °C | -50 to +400 | -50 to +400 |
SafeGap, Normal force Limiter during Gapsetting | - | ✓ | ✓ |
TruRay, Dimmable illumination of sample area | - | ✓ | ✓ |
Connections | USB, Ethernet, RS232, Analog interfaces, Pt100 port | ||
Dimensions | mm | 380 x 660 x 530 | 380 x 660 x 530 |
Weight | kg | 33 | 33 |
QuickConnect for measuring systems, screwless | - | ✓ | ✓ |
ToolmasterTM, measuring system | - | ✓ | ✓ |
ToolmasterTM, measuring cell | - | ✓ | ✓ |
CoolPeltierTM, Peltier-controlled Plate System with built in cooling option that requires no additional accessories for counter-cooling | °C | 25 below ambient temperature but not lower than -5 up to +200 (4 | |
Actively Peltier-controlled hood that requires no additional accessories for counter-cooling | °C | -5 to 200 (4 | |
CoolPeltierTM, Peltier-controlled Cylinder System with built in cooling option that requires no additional accessories for counter-cooling | °C | 15 below ambient temperature but not lower than +5 up to +150 (4 | |
Virtually gradient-free (horizontal, vertical) temperature control | - | ✓ | ✓ |
Rheometer Software: | |||
Test Designer | - | ✓ | ✓ |
Report Designer | - | ✓ | ✓ |
User Management | - | ✓ | ✓ |
Electronic trim lock for the measuring system | - | ✓ | ✓ |
Automatic gap control/setting, AGC/AGS | - | ✓ | ✓ |
Also available as EDU Edition (for educational institutions only):
- MCR 72 or MCR 92 plus accessories with a special academic discount
- Free EDU Toolbox including lab equipment and educational material
1) Depending on sample properties
2) Depending on measuring point duration and sampling time, practically any value is achieved
3) Set frequencies below 10-4 rad/s are of no practical relevance due to the measuring point duration > 1 day
4) System temperature, sample temperature may vary. For measurements at very high or low temperatures a calibration in the sample gap is recommended.
Standards
ASTM
DIN
DIN EN
EN
European Pharmacopoeia (Ph. Eur.)
ICA
IOCCC
ISO
US Pharmacopoeia (USP)
Anton Paar Certified Service
- More than 350 manufacturer-certified technical experts worldwide
- Qualified support in your local language
- Protection for your investment throughout its lifecycle
- 3-year warranty
Documents
-
Beverage | Soft Drinks | Complete Your Soft Drink Analysis Application Reports
-
Calculation of the Critical Shear Rate in a Cylinder Measuring System Application Reports
-
Chocolate Yield-Stress Measurements Depend on Geometry Application Reports
-
Chocolate! How Does It Melt and Flow? Measurements with the MCR 72 Application Reports
-
Coenzyme Q10 - Organic Nanoparticle Characterization Application Reports
-
Determining Flow Behavior of Shampoo Application Reports
-
Determining the Flow Behavior of Coarse Dispersions Application Reports
-
Hair Gel: Viscosity and Yield Point with the MCR 72 Application Reports
-
Measuring the Flow and Recovery of Ketchup with the MCR 72 Application Reports
-
On the use of EC motors in rotational rheometers Application Reports
-
Rheological Tests on Milk Drinks Application Reports
-
Rheology of Coatings: Determining the Yield Point with the MCR 72 Application Reports
-
Rheology of Coatings: Flow Point Determination with the MCR 92 Application Reports
-
Rheology of Coatings: Thixotropic Behavior with the MCR 72 Application Reports
-
Rheology of Thickeners in Pharmaceuticals: Xanthan Gum Application Reports
Similar products
Consumables & Accessories
Consumables & Accessories
Accessories
Accessories
If you do not find the item you require, please contact your Anton Paar sales representative.
To find out if you can purchase online from your location, check the online availability below.
EMP 30 DISPOSABLE MEASURING PLATE DIAMETER:
25 mm
MCR 72/92 MCR 72 | MCR 92
EMP 31 DISPOSABLE MEASURING PLATE DIAMETER:
50 mm
MCR 72/92 MCR 72 | MCR 92
S-LP08/SP/G0 SCREW-ON LOWER MEASURING PLATE
MCR 72/92 MCR 72 | MCR 92
- material: hard anodized aluminium
- suitable for all temperature devices with external thread M60
- with serial number for SmartPave 92
- without groove
S-LP25/SP/G0 SCREW-ON LOWER MEASURING PLATE
MCR 72/92 MCR 72 | MCR 92
- material: hard anodized aluminium
- suitable for all temperature devices with external thread M60
- with serial number for SmartPave series
- without groove
S-LP25/SS/G1 SCREW-ON LOWER MEASURING PLATE
MCR 72/92 MCR 72 | MCR 92
- Material: stainless steel
- Suitable for temperature devices with external thread M60
- With groove on the outer edge (G1), prevents run off of excess material
- Usable with Evaportion Blocker (Mat. No. 251545)
for Peltier heated hood H-PTD220
S-LP50/SS/G1 SCREW-ON LOWER MEASURING PLATE
MCR 72/92 MCR 72 | MCR 92
- Material: stainless steel
- Suitable for temperature devices with external thread M60
- With groove on the outer edge (G1), prevents run off of excess material
- Usable with Evaportion Blocker (Mat. No. 251545)
for Peltier heated hood H-PTD220
S-LP62/SS/G2 SCREW-ON LOWER MEASURING PLATE
MCR 72/92 MCR 72 | MCR 92
- Material: stainless steel
- Suitable for temperature devices with external thread M60
- Round groove (G2) for easy cleaning
S-LP62/SS/G0 SCREW-ON LOWER MEASURING PLATE
MCR 72/92 MCR 72 | MCR 92
- material: stainless steel
- suitable for temperature devices with external thread M60
- without groove (G0)
SILICON MOLD FOR ASPHALT BINDER (PP04)
MCR 72/92 MCR 72 | MCR 92
MEASURING CUP C-CC39/T200/XL/AL
MCR 72/92 MCR 72 | MCR 92
S-LP75/SS/G0 SCREW-ON LOWER MEASURING PLATE
MCR 72/92 MCR 72 | MCR 92
- Material: stainless steel
- Suitable for temperature devices with external thread M60
- Without groove
- Fitting open-end wrench (Mat. No. 174253) included
S-LP25/SS/P2/G1
MCR 72/92 MCR 72 | MCR 92
- material: stainless steel
- suitable for all temperature devices with external thread M60
S-LP25/SS/S/G1 SCREW-ON LOWER MEASURING PLATE
MCR 72/92 MCR 72 | MCR 92
- Material: stainless steel
- Sandblasted surface
- Suitable for temperature devices with external thread M60
- With groove on the outer edge (G1), prevents run off of excess material
- Usable with Evaportion Blocker (Mat. No. 251545)
for Peltier heated hood H-PTD220
STIRRER ST22-6V-16/106 (HAAKE FL 100)
MCR 72/92 MCR 72 | MCR 92
VISCOSITY STANDARD DKD 2000 AW 100 ml - 1500 / 460 / 45 mPa.s
MCR 72/92 MCR 72 | MCR 92
VISCOSITY STANDARD DKD 2000 AW 250 ml - 1500 / 460 / 45 mPa.s
MCR 72/92 MCR 72 | MCR 92
MEASURING CUP HOLDER H-CC27/XL/D
MCR 72/92 MCR 72 | MCR 92
DISPOSABLE/REMOVEABLE CONE D-CP40-1/SS/S07
MCR 72/92 MCR 72 | MCR 92
DISPOSABLE/REMOVEABLE CONE D-CP25-2/SS/S07
MCR 72/92 MCR 72 | MCR 92
STIRRER ST22-4V-16/106 (HAAKE FL 100)
MCR 72/92 MCR 72 | MCR 92
SELF-LOCKING COUPLING
MCR 72/92 MCR 72 | MCR 92
MEASURING CUP C-CC39/T200/XL/SS
MCR 72/92 MCR 72 | MCR 92
CONNECTION KIT FOR FLUID CIRCULATORS
MCR 72/92 MCR 72 | MCR 92
MEASURING SHAFT BC 12.7 D:
12,7 mm
MCR 72/92 MCR 72 | MCR 92
DISPOSABLE DISHES 80 mm 1 PACK = 100 PIECES
MCR 72/92 MCR 72 | MCR 92
DISPOSABLE MEASURING CUP C-CC27/D/AL ASPHALT
MCR 72/92 MCR 72 | MCR 92
DISPOSABLE PLATE D-PP08/AL/P2/S07 D:
8 mm; PROFILED
MCR 72/92 MCR 72 | MCR 92
DISPOSABLE/REMOVEABLE PLATE D-PP50/SS/S07
MCR 72/92 MCR 72 | MCR 92
DISPOSABLE PLATE D-PP10/AL/07 1 pack = 10 pcs
MCR 72/92 MCR 72 | MCR 92
DISPOSABLE CONE D-CP25-1/AL/S07 D:
25 mm, ANGLE 1°, 1 pack = 10 pcs
MCR 72/92 MCR 72 | MCR 92
INSET I-PP25/SS/S D:
25 mm; SANDB
MCR 72/92 MCR 72 | MCR 92
DISPOSABLE PLATE D-PP05/AL/S07 D:
5 mm, 1 pack = 10 pcs
MCR 72/92 MCR 72 | MCR 92
S-LP25/AL/P2/G1
MCR 72/92 MCR 72 | MCR 92
- material: hard anodized aluminium
- suitable for all temperature devices with external thread M60
- with groove on the outer edge (G1), prevents run off of excess material
- usable with Evaportion Blocker for Peltier heated hood H-PTD220
S-LP50/AL/P2/G1
MCR 72/92 MCR 72 | MCR 92
- material: hard anodized aluminium
- suitable for all temperature devices with external thread M60set 50 mm perfilado
- with groove on the outer edge (G1), prevents run off of excess material
- usable with Evaportion Blocker for Peltier heated hood H-PTD220"
S-LP25/AL/S/G1
MCR 72/92 MCR 72 | MCR 92
- material: hard anodized aluminium
- suitable for all temperature devices with external thread M60
- with groove on the outer edge (G1), prevents run off of excess material
- usable with Evaportion Blocker for Peltier heated hood H-PTD220
S-LP50/AL/S/G1
MCR 72/92 MCR 72 | MCR 92
- material: hard anodized aluminium
- suitable for all temperature devices with external thread M60
- with groove on the outer edge (G1), prevents run off of excess material
- usable with Evaportion Blocker for Peltier heated hood H-PTD220
S-LP62/AL/P2/G0
MCR 72/92 MCR 72 | MCR 92
- material: hard anodized aluminium
- suitable for all temperature devices with external thread M60
- without groove
DUST COVER MCR RHEOMETERS SUITABLE FOR MCR 52/72/92/102/302/102e
MCR 72/92 MCR 72 | MCR 92
P-PTD 220/AIR FOR MCR x2 PELTIER TEMPERATURE DEVICE (PLATE)
MCR 72/92 MCR 72 | MCR 92
- plate with active Peltier temperature control (heating/cooling)
- for cone/plate and parallel plate measuring geometries
- with built-in fan for air counter-cooling
- with universal plate holder (screw-on thread) for use of measuring plates (also disposable) and other accessories
- with Toolmaster for automatic tool recognition and configuration
- installation in the rheometer through three-point support without the risk of misalignment
- maximized torsional stiffness due to constructional torque support
C-PTD 150/XL/AIR/18P AIR COOLED PELTIER TEMPERATURE DEVICE
MCR 72/92 MCR 72 | MCR 92
- with integrated fan for counter cooling CoolPeltier
- temperature range: +5*) to 150 °C
*) The lower temperature range depends on the ambient conditions.
MEASURING CUP HOLDER MBA-Z4-C
MCR 72/92 MCR 72 | MCR 92
Optical accessory for MCR:
Rheometer-Infrared Spectrometer Adapter
MCR 72/92 MCR 72 | MCR 92
- Accessory for structure analysis and rheo optics
- Lets you connect your infrared spectrometer with an MCR rheometer
- Investigates the chemical composition and rheology
INSET I-PP08/SS(WITH GROOVE) D:
8 mm; STAINLESS STEEL
MCR 72/92 MCR 72 | MCR 92
Accessory for MCR and RheolabQC:
Flexible Cup Holder
MCR 72/92 MCR 72 | MCR 92
- Accessory for “Extended Material Characterization"
- Holds, for example: paint cans, yogurt cups, other containers
- Can be combined with stirrers, concentric cylinder geometries, and a Pt100 temperature sensor
MEAS. CYLINDER B-CC28.72-15 D:
28.72 mm; L1: 15 mm
MCR 72/92 MCR 72 | MCR 92
Peltier Temperature Devices for MCR 72/92:
PTD
MCR 72/92 MCR 72 | MCR 92
- CoolPeltier™ technology ensures accurate, efficient temperature control
- Compatible with MCR 72 and MCR 92 rheometers for precise measurements
- Supports various measuring systems
- Ideal for a wide range of sample consistencies: no need for liquid cooling
MEASURING CONE CP75-1 D:
75 mm; ANGLE 1°
MCR 72/92 MCR 72 | MCR 92
MEAS. CYLINDER B-CC27 D:
26.66 mm
MCR 72/92 MCR 72 | MCR 92
LOWER MEASURING PLATE L-PP08/CTD D:
8 mm; FOR CTD450/600/1000
MCR 72/92 MCR 72 | MCR 92
Accessory for MCR:
Rheometer Geometries
MCR 72/92 MCR 72 | MCR 92
- Wide range of measuring systems for RheolabQC and the MCR rheometer series
- Concentric cylinder, double-gap, cone-plate, and parallel-plate systems, vane geometries and spindles, Krebs spindles
- Customized solutions upon request
MEASURING PLATE PP40 D:
40 mm
MCR 72/92 MCR 72 | MCR 92
INSET I-PP80/SS D:
80 mm; STAINLESS STEEL
MCR 72/92 MCR 72 | MCR 92
MEASURING PLATE PP15 D:
15 mm
MCR 72/92 MCR 72 | MCR 92
STANDARD MEASURING SYSTEM CC39/T200/XL/SS
MCR 72/92 MCR 72 | MCR 92
- measuring cylinder B-CC39/Q1
- measuring cup C-CC39/T200/XL/SS
MEASURING CONE CP25-2 D:
25 mm; ANGLE 2°
MCR 72/92 MCR 72 | MCR 92
MEASURING PLATE PP20 D:
20 mm
MCR 72/92 MCR 72 | MCR 92
INSET I-PP25/SS D:
25mm; stainless steel.
MCR 72/92 MCR 72 | MCR 92
MEASURING CONE CP60-1/Q1 D:
60mm; CONE ANGLE: 1°
MCR 72/92 MCR 72 | MCR 92
COVER / SOLVENT TRAP 80 mm PEEK|FOR P-PTD 200 / P-PTD 220
MCR 72/92 MCR 72 | MCR 92
- suitable up to 220 °C and solvent-based samples
- suitable as solvent trap for PP/CP measuring geometries > 25 mm
- suitable as cover for all PP/CP measuring geometries up to 75 mm
- can be put in place after sample loading and trimming
- can not be used in combination with active Peltier hood
INSERT I-PP50/SS D:
50mm; stainless steel.
MCR 72/92 MCR 72 | MCR 92
SHAFT FOR DISPOSABLE MEASURING- SYSTEMS D-CP/PP 7, WITHOUT TOOLMASTER
MCR 72/92 MCR 72 | MCR 92
MEASURING PLATE PP04 D:
4 mm
MCR 72/92 MCR 72 | MCR 92
MEASURING PLATE PP25/P2 D:
25 mm, PROFILED: 1X0.5
MCR 72/92 MCR 72 | MCR 92
MEASURING CONE CP60-0.5 D:
60 mm; ANGLE 0.5°;
MCR 72/92 MCR 72 | MCR 92
MEASURING CONE CP40-0.3 D:
40 mm; ANGLE 0.3°
MCR 72/92 MCR 72 | MCR 92
MEASURING PLATE PP25/S D:
25 mm, SANDBLASTED
MCR 72/92 MCR 72 | MCR 92
MEASURING CONE CP50-1 D:
50 mm; ANGLE 1°
MCR 72/92 MCR 72 | MCR 92
MEASURING CONE CP50-2 D:
50 mm; ANGLE 2°
MCR 72/92 MCR 72 | MCR 92
MEASURING CONE CP35-1 D:
35 mm; ANGLE 1°
MCR 72/92 MCR 72 | MCR 92
MEASURING CONE CP25-1 D:
25 mm; ANGLE 1°
MCR 72/92 MCR 72 | MCR 92
MEASURING PLATE PP25 D:
25 mm
MCR 72/92 MCR 72 | MCR 92
MEASURING CUP C-CC27/T200/XL/SS
MCR 72/92 MCR 72 | MCR 92
MEASURING CUP C-CC27/T200/XL/AL
MCR 72/92 MCR 72 | MCR 92
MEASURING PLATE PP50 D:
50 mm
MCR 72/92 MCR 72 | MCR 92
LOWER MEASURING PLATE L-PP50/CTD D:
50 mm; NO GROOVE; FOR CTD450/600
MCR 72/92 MCR 72 | MCR 92
MEASURING CONE CP25-0.5 D:
25 mm; ANGLE 0.5°
MCR 72/92 MCR 72 | MCR 92
MEASURING PLATE PP12 D:
12 mm
MCR 72/92 MCR 72 | MCR 92
MEASURING CUP C-CC27/SS/AIR
MCR 72/92 MCR 72 | MCR 92
INSET I-PP04/CU/CX(WITH GROOVE) D:
4 mm; COPPER ALLOY, COATED
MCR 72/92 MCR 72 | MCR 92
MEASURING CUP HOLDER H-CC27/D
MCR 72/92 MCR 72 | MCR 92
MEASURING SYSTEM CC27/SS FOR C-PTD 180/AIR
MCR 72/92 MCR 72 | MCR 92
- measuring cylinder B-CC27/Q1
- measuring cup C-CC27/SS/AIR
MEASURING CONE CP20-0.5 D:
20 mm; ANGLE 0.5°
MCR 72/92 MCR 72 | MCR 92
MEASURING SYSTEM DG26.7 FOR C-PTD 180/AIR
MCR 72/92 MCR 72 | MCR 92
- measuring cylinder B-DG26,7/Q1
- measuring cup C-DG26,7/AIR
MEASURING PLATE PP08 D:
8 mm
MCR 72/92 MCR 72 | MCR 92
H-PTD 200/AIR/18P AIR-COOLED PELTIER HOOD
MCR 72/92 MCR 72 | MCR 92
- with integrated fan for counter cooling CoolPeltier,
- incl. flow valve,
- temperature range: -5* to 200 °C.
* Lower temperature range depends on ambient conditions.
INSET I-PP60/SS D:
60 mm; STAINLESS STEEL
MCR 72/92 MCR 72 | MCR 92
MEAS. CYLINDER B-CC17 D:
16.66 mm
MCR 72/92 MCR 72 | MCR 92
MEASURING PLATE PP50/P2 D:
50 mm, PROFILED: 1X0.5
MCR 72/92 MCR 72 | MCR 92
DISPOS. LOWER MEASURING PLATE L-PP08/D/AL/CTD
MCR 72/92 MCR 72 | MCR 92
MEASURING PLATE PP50/S D:
50 mm, SANDBLASTED
MCR 72/92 MCR 72 | MCR 92
MEASURING CONE CP40-2 D:
40 mm; ANGLE 2°
MCR 72/92 MCR 72 | MCR 92
MEASURING CONE CP50-0.5 D:
50 mm; ANGLE 0.5°
MCR 72/92 MCR 72 | MCR 92
MEASURING CONE CP40-1 D:
40 mm; ANGLE 1°
MCR 72/92 MCR 72 | MCR 92
INSET I-PP50/CU/CX D:
50 mm; COPPER ALLOY, COATED
MCR 72/92 MCR 92
SPATULA
MCR 72/92 MCR 72 | MCR 92
STANDARD MEASURING SYSTEM CC39/T200/XL/AL
MCR 72/92 MCR 72 | MCR 92
- measuring cylinder B-CC39/Q1
- measuring cup C-CC39/T200/AL